Environmental noise and light in an university printing workshop in San José, Costa Rica
DOI:
https://doi.org/10.22458/urj.v3i1.207Keywords:
Working environment, physical agents, university printing workshop.Abstract
Concern for inadequate exposure to physical factors in the working environment began in the mid 20th. Century. The subject has been widely studied in industrial nations, but in Central America there are few published studies, so we measured two environmental factors in a university press workshop in Costa Rica, from April 05 to 16, 2010, a period in which production is high. With a calibrated Extech HD450 light meter we did at least three measurements of light along the workday (considering changes in natural lighting). We selected the measurement points where certain illumination is needed for proper operation of industrial machinery. We also made 20 real-time measurements of noise with a certified Extech sound meter, in the offset press room, where there is noisy industrial machinery. We found inadequate noise and lighting levels, and concluded that staff are exposed to inappropriate health conditions, so we recommend the relocation of lamps and periodical audiometric tests.
References
Ahmed, H.O., J.H. Dennis, O. Badran, M. Ismail, S.G. Ballal, A. Ashoor & D. Jerwood. 2001. Occupational noise exposure and hearing loss of workers in two plants in eastern Saudi Arabia. Occupational Hygienic 45: 371-380.
Arce, L. & J. Monge. 2010. Lighting and noise level in the central facilities of the Costa Rican Distance Education University: health implications for staff and students. Cuadernos de Investigación UNED 2: 63-68.
Babisch, W., B. Beule, M. Schust, N. Kersten & H. Ising. 2005.Traffic Noise and Risk of Myocardial Infarction. Epidemiology 16: 33-40.
Belojevi, G.A, B. D. Jakovljevi, V. J. Stojanov, V. Slepevic & K. Paunovi. 2008. Nighttime Road-Traffic Noise and Arterial Hypertension in an Urban Population. Hypertension Research 31: 775–781.
Chacín-Almarza, B., G. Corzo-Álvarez, L. Rojas-González, E. Rodríguez-Chacín & G. Corzo-Ríos. 2002. Estrés organizacional y exposición a ruido en trabajadores de la planta de envasado de una industria cervecera. Investigación Clínica 43: 271-289.
Chávez, R. 2006. Ruido: Efectos sobre la salud y criterio de su evaluación al interior de recintos. Ciencia y Trabajo 8: 42-46.
De Kluizenaar, Y., S.A. Janssen, F.J. van Lenthe, H.M. Miedema & J.P Mackenbach. 2009. Long-term road traffic noise exposure is associated with an increase in morning tiredness. Journal of the Acoustics Society of America 126: 626-633.
Emanuel, E.J., D. Wendler & C. Grady. 2000. What makes clinical research ethical? JAMA 283: 2701-2711.
Guerrero, R., F.G. Aliev, Y. Tserkovnyak , T.S. Santos & J.S. Moodera. 2006. Shot Noise in Magnetic Tunnel Junctions: Evidence for Sequential Tunneling. Physical Review Letters 97.
Hernández, H. & M. Gutiérrez. 2006. Hipoacusia inducida por ruido, estado actual. Revista Cubana Médica Militar 35: 4-10.
Instituto de Normas Técnicas de Costa Rica. 2000. Norma INTE 31-08-06-2000. Niveles de iluminación que deben tener los centros de trabajo. Instituto de Normas Técnicas de Costa Rica, San José, Costa Rica.
INTECO (Instituto de Normas Técnicas de Costa Rica). 2000. Norma INTE 31-09-16-2000. Condiciones de seguridad e higiene en los centros de trabajo donde se genere ruido. Instituto de Normas Técnicas de Costa Rica, San José, Costa Rica.
La Torre, G., U. Moscato, F. La Torre, P. Ballini, S. Marchi & W. Ricciardi. 2007. Environmental noise exposure and population health: a cross-sectional study in the Province of Rome. Journal of Public Health 15: 339-344.
Loera-González, M.A., S. Salinas-Tovar, G. Aguilar-Madrid & V.H. Borja-Aburto. 2002. Hipoacusia por trauma acústico crónico en trabajadores afiliados al IMSS, 1992-2002. Revista Médica [México] 44: 497-504.
Montiel-López, M., G. Corzo-Alvarez, B. Chacín-Almarza, L. Rojas-González, A. Quevedo, A. Lubo-Palma & H. Rendiles. 2006. Prevalencia y caracterización de la pérdida auditiva en trabajadores expuestos a ruido industrial de una planta eléctrica turbogenerada en un complejo petroquímico. Investigación Clínica 47: 117-131.
Otárola, F., F. O. Zapata & A. Finkelstein. 2008. Ruido laboral y su impacto en salud. Ciencia y Trabajo 20: 47-51.
Rodríguez, L. & J. Alonzo. 2004. Efecto de los factores ambientales, laborales y psicosociales, en el síndrome del edificio enfermo. Ingeniería Revista Académica 8: 1-6.
Selander, J., G. Bluhm, T. Theorell, G. Pershagen, W. Babisch, I. Seiffert, D. Houthuijs, O. Breugelmans, F. Vigna-Taglianti, M. Antoniotti, E.Velonakis, E. Davou, M.Dudley & L. Järup. 2009. Saliva Cortisol and Exposure to Aircraft Noise in Six European Countries. Environmental Health Perspectives 117: 1713-1717.
Stansfeld, S. 2006. Exploring the Link Between Environmental Noise and Psychiatric Disorder. Psychiatric Times 23: 1-2.
Su, S., C. Lu, J. Sheen, S. Kuo & H. Guo. 2006. Tear secretion dysfunction among women workers engaged in light-on tests in the TFT-LCD industry. BMC Public Health 6: 303-310.
Van Bommel, W. & G. Van den Beld. 2004. Lighting for work: a review of visual and biological effects. Lighting Research and Technology 36: 255 - 269.
Wang, Y.G. & P.P. Zhang. 2007. Study on parking apron operation hazard management. Journal of Safety and Environment 7: 131-133.
Downloads
Published
How to Cite
Issue
Section
License
Note: This abstract contains an incorrect copyright due to technical issues. Authors who publish with this journal agree to the following terms: Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal
All journal contents are freely available through a CC BY 4.0 license.
CC BY 4.0 is a Creative Commons: you can copy, modify, distribute, and perform, even for commercial reasons, without asking permission, if you give appropriate credit.
Contents can be reproduced if the source and copyright are acknowledged according to the Open Access license CC BY 4.0. Self-storage in preprint servers and repositories is allowed for all versions. We encourage authors to publish raw data and data logs in public repositories and to include the links with all drafts so that reviewers and readers can consult them at any time.
The journal is financed by public funds via Universidad Estatal a Distancia and editorial independence and ethical compliance are guaranteed by the Board of Editors, UNED. We do not publish paid ads or receive funds from companies.